sicastar®-M-CT
Cluster-typed magnetic silica particles (sicastar®-M-CT)
- consist of aggregates in the size range of 3 – 30 µm with a mean diameter of 6 microns,
- are produced by hydrolysis of orthosilicates in the presence of magnetite,
- show a homogeneous distribution of magnetite in the silica matrix by the special preparation method,
- have a hydrophilic surface with terminal Si-OH-bonds,
- can easily be separated even in highly viscous media with conventional permanent magnets,
- are extremely stable in organic solvents and at high temperatures,
- are designed with the surface functionalities OH (plain), NH2, COOH and epoxy for the covalent binding of proteins, antibodies or other molecules,
- can be offered with the nickel-(II)-complex of nitrilotriacetic acid (Ni-NTA) for the binding of histidine labeled proteins,
- are available with a hydrophobic octadecyl (C18) surface.
showing all 6 results
References
- G. Mistlberger and I. Klimant, Luminescent magnetic particles: structures, syntheses, multimodal imaging, and analytical applications, Bioanal Rev, 2010, 2(61–101;
- V. Böhmer, J.-F. Dozol, C. Grüttner, K. Liger, S. E. Matthews, S. Rudershausen, M. Saadioui and P. Wang, Separation of lanthanides and actinides using magnetic silica particles bearing covalently attached tetra-CMPO-calix[4]arenes, Org. Biomol. Chem., 2004, 2(2327–2334;
- C. Grüttner, V. Böhmer, A. Casnati, J.-F. Dozol, D. N. Reinhoudt, M. M. Reinoso-Garcia, S. Rudershausen, J. Teller, R. Ungaro and W. Verboom, Dendrimer-coated magnetic particles for radionuclide separation, Journal of magnetism and magnetic materials, 2005, 293(1), 559–566;
- C. Grüttner, S. Rudershausen, S. Matthews, P. Wang, V. Böhmer and J. Dozol, Selective extraction of lanthanides and actinides by magnetic silica particles with CMPO-modified calix [4] arenes on the surface, European Cells and Materials, 2002, 3(2), 48–51;
- S. E. Matthews, P. Parzuchowski, A. Garcia-Carrera, C. Grüttner, J.-F. Dozol and V. Böhmer, Extraction of lanthanides and actinides by a magnetically assisted chemical separation technique based on CMPO-calix [4] arenesElectronic supplementary information (ESI) available: full synthetic procedures and extraction studies. See http://www. rsc. org/suppdata/cc/b0/b009679m, Chemical Communications, 2001, 5), 417–418;
- M. M. Reinoso-García, D. Jańczewski, D. N. Reinhoudt, W. Verboom, E. Malinowska, M. Pietrzak, C. Hill, J. Báča, B. Grüner and P. Selucky, CMP (O) tripodands: synthesis, potentiometric studies and extractions, New journal of chemistry, 2006, 30(10), 1480–1492;
Sub categories:
-
COOH (1)
-
epoxy (1)
-
NH2 (1)
-
Ni-NTA (1)
-
NTA (1)
-
plain (1)
| Product ID | Name | Surface | Diameter | Concentration | Amount | Price | TDS | MSDS | Order |
|---|---|---|---|---|---|---|---|---|---|
| 59-00-603 | sicastar®-M-CT | plain | 6 µm | 50 mg/ml | 10 ml | 198,00 € |
|
|
Add to cart |
| 59-01-603 | sicastar®-M-CT | NH2 | 6 µm | 50 mg/ml | 10 ml | 222,00 € |
|
|
Add to cart |
| 59-02-603 | sicastar®-M-CT | COOH | 6 µm | 50 mg/ml | 10 ml | 222,00 € |
|
|
Add to cart |
| 59-08-603 | sicastar®-M-CT | epoxy | 6 µm | mg/ml | 0,5 ml | 238,00 € |
|
|
Add to cart |
| 59-48-603 | sicastar®-M-CT | Ni-NTA | 6 µm | 50 mg/ml | 10 ml | 317,00 € |
|
|
Add to cart |
| 59-11-603 | sicastar®-M-CT | NTA | 6 µm | 50 mg/ml | 10 ml | 281,00 € |
|
|
Add to cart |